Test & Mesure

SA nScope Line

Séminaires Techniques

Tutoriels

Syndication

  • Flux RSS des articles
Mardi 20 mai 2008 2 20 /05 /Mai /2008 13:04

Presentation Powerpoint:

EMC-pulse-measurements.pdf EMC-pulse-measurements.pdf


Leading Features

  • Fast and Accurate EMC pulse verification
  • Customizable Rise, Fall, and Width parameters
  • Histogram up to 2 billion events

Electrostatic Discharge (ESD)
High sample rate and bandwidth are important to accurately characterize pulse shapes created with an ESD generator. The software package offers specialized parameters with adjustable levels that allow you to customize the necessary rise time, fall time, and width measurements to ensure that the generator meets industry standards. Built-in statistics and histicons provide the ability to quickly view a large number of measurements at a single glance.


Electrical Fast Transient (EFT)
The fast rise times of EFT pulses, along with the repetition rates of EFT bursts, require an oscilloscope with both high sample rate and long memory to accurately capture the waveforms. The long memory available in X-Stream Digital Oscilloscopes, along with sequence acquisition mode, enable the capture of many EFT bursts in a short period of time. Specialized rise, fall, and width pulse parameters, added with the software package and combined with statistics and histicons, allow for fast pulse measurements over all bursts. X-Stream Digital Oscilloscopes’ built-in zoom capabilities allow you to quickly locate and view any pulses that may fall out of spec.

La suite
ici .



Par LeCroy France - Publié dans : Applications
Ecrire un commentaire - Voir les 0 commentaires
Mardi 22 avril 2008 2 22 /04 /Avr /2008 15:05






La lettre électronique de LeCroy | Volume 3-2008
Pour plus d'informations sur un de ces produits, >>cliquez ici

 Pleins feux sur:

Huit Oscilloscopes >>M-Type de 200 MHz à 2 GHz très bien équipés pour le débogage, la validation et la documentation des mesures
Conçu pour s'afficher comme l'instrument le plus versatile de sa catégorie, la série M-Type dispose d'une suite d'outils d'analyse, de solutions applicatives et d'outils innovants tels que >>WaveScan et >>LabNotebook (Documentation & Rapports).
Regardez la série M-Type en action >>cliquez ici

Regardez la recherche WaveScan en action >>cliquez ici

>> WaveRunner MXi
• Bande passante 400 MHz - 2 GHz
• Jusqu'à 10 GEch/s
• Mémoire standard de 25 Mpts
• Maths avancées, Analyse de gigue, Personnalisation, HDTV
• Recherche & analyse >>WaveScan et génération de rapports >>LabNotebook
• >>Options signaux mixtes 18/36 Voies
• Options >>I2C, >>SPI, >>UART, >>LIN, >>CAN, >>FlexRay
>> WaveSurfer MXs
• Bande passante 200 MHz - 1 GHz
• Jusqu'à 4x 5 GEch/s
• Mémoire standard de 10 Mpts/voie
• Math avancées, déclenchement avancé, HDTV
• Recherche & analyse >>WaveScan et génération de rapports >>LabNotebook
• >>Options signaux mixtes 18/36 Voies
• Options >>I2C, >>SPI, >>UART, >>LIN, >>CAN

 Nouveautés oscilloscopes:

Promotions de printemps sur les oscilloscopes

Vente d'oscilloscopes de démonstration 3 GHz et 6 GHz

Nouvelle option pour le test, le décodage et l'analyse des couches physiques FlexRay

LeCroy étend la gamme des tests de conformité automatisés par QualiPHY avec maintenant Serial ATA, UltraWideband et PCI-Express Gen 1
Nouveaux articles techniques:

• >>Améliorer les analyses spectrales faites par les oscilloscopes
• >>DesignCon 2008: Méthode de validation pour les paramètres S sur ligne de transmission
• >>Transmission par fibre d'un signal radio UWB 480 Mbps avec l'utilisation d'un transducteur à électro-absorbtion réflective de 1310/1550nm et des composants du commerce

L'oscilloscope sampling LeCroy WaveExpert 100H gagne le 18ème prix de l'innovation de EDN magazine
LeCroy Reçoit l'approbation PCI-SIG pour la solution de conformité PCI-Express Gen 2

 Nouveautés analyse de protocole:

LeCroy améliore le système de verification UWBTracer/Trainer avec l'enregistrement Spool-to-disk et le vérificateur de conformité UWBSpekChekT

Ensemble des solutions d'analyse de protocole LeCroy

Nouvelles notes d'applications

Cette offre s'applique aux modèles sélectionnés et ne peut être combine avec d'autres offres.



Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Lundi 21 avril 2008 1 21 /04 /Avr /2008 10:56
Après avoir introduit les versions WaveSurfer 104MXs et WaveRunner 104MXi,, nous venont compléter ces deux séries d'oscilloscopes numériques quatre voies avec, au total, six nouveaux modèles supplémentaires.
Il s'agit, pour les WaveSurfer MXs des versions:
  • 24MXs (200MHz, 2,5Géch/s, 10Mpoints/voie)
  • 44MXs (400MHz, 2,5Géch/s, 10Mpoints/voie)
  • 64MXs (600MHz, 2,5Géch/s ou 5Géch/s avec les voies entrelacées, 10Mpoints/voie)
et, pour les WaveRunner, des versions:
  • 44MXs (400MHz, 5Géch/s, 12,5Mpoints/voie)
  • 64MXs (600MHz, 5Géch/s ou 10Géch/s avec les voies entrelacées, 12,5Mpoints/voie)
  • 204MXs (2GHz, 5Géch/s ou 10Géch/s avec les voies entrelacées, 12,5Mpoints/voie).
La particularité des séries M comparé aux WaveSurfer Xs et WaveRunner Xi existantes réside dans la présence en standard d'une multitude de fonctionnalités de mesure et d'analyse:
  • la technologie de recherche WaveScan

Rechercher des données peut être utile, mais ne serait-il pas plus judicieux de rechercher ce qu’un déclenchement ne peut pas trouver ? WaveScan vous permet d’effectuer une recherche dans une seule acquisition en utilisant plus de 20 modes de recherche différents. Vous pouvez également configurer une condition de recherche et la lancer sur un événement pendant plusieurs heures ou plusieurs jours. Ensuite, une fois l’événement trouvé, vous effectuez l’action voulue.

Plus d’informations sur la fonction WaveScan >










  • l'affichage WaveStream

La fonction WaveStream permet d’obtenir un affichage éclatant avec gradation d’intensité (en 256 niveaux) ainsi qu’une mise à jour rapide pour reproduire fidèlement l’aspect et le rendu d’un oscilloscope analogique. Activez ou désactivez la fonction WaveStream et ajustez l’intensité via le bouton du panneau avant. Utilisez ce mode uniquement lorsque vous en avez besoin.

Plus d’informations sur la fonction WaveStream >


  • l'outil de création et de génération de rapport LabNotebook
  • et de nombreuses fonctions de mathématiques et de mesure.
Pour Les WaveSurfer MXs: HDTV Trigger, Fonctions Math et Mesures évolués dont la FFT sur 1 Mpts, la possibilité de chaîner deux fonctions Math.

Pour Les WaveSurfer MXi: HDTV Trigger, Fonctions Math et Mesures évolués dont la FFT sur 25 Mpts, les possibilités très évoluer sur les paramètres, les Histrogrammes avec 19 paramètres histrogrammes, Pack Customisation ( Possibilité de création de ses propres paramètre de mesure ou fonction Math avec VBScript-MATLAB-Excel-Mathcad et le pack d'Analyse de Jitter & Timming .


De plus vous pouvez rajouter divers options et sondes:

Option oscilloscope à signaux mixtes  

Complétez les 4 canaux habituels du WaveSurfer Xs avec 18 ou 36 canaux numériques supplémentaires grâce à l’option oscilloscope à signaux mixtes MS-250 et Ms-500.

Disponible en deux versions, la nouvelle série d’oscilloscopes mixtes haute performance MS ajoute de puissants outils aux WaveRunner Xi et WaveSurfer Xs pour les applications embarquées. Le MS-500, avec une fréquence d’entrée maximum de 500 MHz, est deux fois plus rapide que n’importe quel autre oscilloscope à signaux mixtes. Cette fréquence de 500 MHz est parfaite pour les développements embarqués d’aujourd’hui ; de plus, une mémoire de 50 Mpts/voie permet de capturer jusqu’à 25 ms de signaux logiques à pleine vitesse d’échantillonnage, simultanément sur les 18 voies.  Pour encore plus de souplesse, le MS-500 peut fonctionner en mode 36 voies. Encore une performance deux fois supérieure à l’offre actuelle sur le marché des oscilloscopes mixtes. Le MS-250 offre un temps d’acquisition de 10 ms à pleine vitesse, soit 250 MHz, sur 18 voies.

Contrairement à d’autres solutions qui obligent l’utilisateur à réduire la mémoire des voies analogiques au profit des voies  logiques, les nouvelles solutions mixtes pour séries WaveRunner Xi et WaveSurfer Xs gardent disponible toute la mémoire originale de l’oscilloscope à tout moment. C’est la solution la plus performante du marché pour les mesures simultanées et synchronisées de signaux logiques et analogues de longue durée.


Plus d’informations sur l’option MS-250/MS-500 >


Déclenchement et décodage I2C, SPI et CAN (en option)

Les fonctionnalités de déclenchement série I2C, SPI et CAN, parmi lesquelles le déclenchement conditionnel sur données pour bus I2C et CAN, simplifie l’isolation d’événements spécifiques sur votre contrôleur embarqué. Déclenchez sur la ligne DATA dans des emplacements spécifiques de longues lectures EEPROM I2C ou déclenchez sur des valeurs de capteur I2C en dehors d’une certaine fourchette. La superposition de décodages intuitive à code couleurs vous aide à comprendre vos signaux de données série rapidement. Recherchez des schémas de données ou affichez les données de protocole sous forme de tableau. Exportez les données du tableau vers un fichier Excel. (Autres fonctionnalités en option).

Plus d’informations sur I²C et SPI >

Plus d’informations sur LIN >

Plus d’informations sur CAN >
 


Série ZS de sondes actives à haute impédance (accessoires)

La nouvelle série ZS de sondes actives à haute impédance de LeCroy fournit une pleine bande passante à la pointe de la sonde et une haute impédance (1 MW || 0,9 pF) désirée. Une gamme de pointes de sonde de série ou en option ainsi que des accessoires de mise à la masse sont proposés pour répondre à tous vos besoins. De plus, les sondes de la série ZS sont disponibles à un coût très modeste. Utilisez la ZS1000 avec les WaveSurfers 200 à 600 MHz et la ZS1500 avec les WaveSurfers 1 GHz pour permettre à la pointe de la sonde de bénéficier d’une pleine bande passante.

Plus d’informations sur les séries de sonde ZS >
 


Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Lundi 21 avril 2008 1 21 /04 /Avr /2008 10:49

Embedded Systems Conference, San Jose, CA, April 15, 2007 - LeCroy Corporation, a leading supplier of oscilloscopes and serial protocol solutions, announced that the PCI-SIG®, the Special Interest Group responsible for PCI Express, has approved the LeCroy Protocol Test Card (PTC) as its standard test tool for PCI Express 2.0 protocol verification. LeCroy's new PTC has been developed in close collaboration with the Intel Corporation and PCI Express Industry, and is specifically designed to meet industry requirements for next generation development tools for PCI Express.

"The introduction of LeCroy's Protocol Test Card will provide developers with an official test tool for PCIe 2.0 compliance testing later this fall," said Al Yanes, PCI-SIG president and chairman. "We are pleased to see LeCroy's continued investment in developing testing tools that help expedite the industry adoption of PCIe 2.0."

This new tool will be used by validation and test engineers to check for functionality of add-in cards, systems, and chips that use PCI Express 2.0. A newly-added user interface makes running the link, transaction and BIOS tests much simpler, allowing all tests to be selected from an intuitive menu and then run by simply pushing a button. A descriptive report can be generated indicating which of the tests were passed or failed.

"As the world leader in visual computing, NVIDIA® has a long history of driving innovations related to PCI-Express," said Michael Diamond, director of strategic marketing, NVIDIA Corporation. "LeCroy contributes to our ability to ensure the broadest compatibility for our GeForce®, Quadro®, and Tesla™ product families, and LeCroy PTC's new and improved interface has made it easier for our engineers to run PCI-Express Gen2 product tests and understand the test results."

“The PCI Express 2.0 technology is becoming the 'new standard' in I/O connectivity,” said Jim Pappas, Director of Technology Initiatives at Intel Corporation. “Compliance tools like the LeCroy PCI Express 2.0 PTC will help lay a sure interoperability foundation that the industry can build on going forward."

“LeCroy has actively supported the PCI-SIG for the last several years with protocol and electrical compliance tools. We are very pleased that our PTC has been selected as a standard for testing PCI Express 2.0 protocol compliance,” said Carmine Napolitano, General Manager of Protocol Solutions Group, LeCroy Corporation. “The LeCroy PTC completes our comprehensive suite of analysis tools for PCI Express 2.0.”

LeCroy protocol analyzers and exercisers have been at the forefront of PCI Express development. All LeCroy protocol analyzers feature a hierarchical display, real-time statistics, protocol traffic summaries, detailed error reports, powerful scripting, and the ability to create user-defined test reports, which allow developers to troubleshoot intricate problems and finish their projects on time.

U.S. Pricing and Availability

The LeCroy PTC for PCIe 2.0 is available now. Pricing starts at $7,999.

For additional information, contact LeCroy at 1-800-5LeCroy (1-800-553-2769) or visit LeCroy’s web site at www.lecroy.com

Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Mardi 1 avril 2008 2 01 /04 /Avr /2008 16:01
"Séminaire pratique concrète de l’oscilloscope"

  • Comment faire des mesures rapides et précises avec un oscilloscope ?
  • Comment éviter les erreurs de mesures ?
  • Choisir la sonde adaptée à l’application ?
  • Que peut-on attendre d’un oscilloscope d’usage général ?
  • Comment documenter les résultats des mesures ?

Notre séminaire d’une journée vous apportera des réponses concrètes et pratiques à des questions essentielles sur l’utilisation d’un oscilloscope. Enregistrez-vous dès aujourd’hui.
http://www.distrame.fr/emailing/invitation_formation_LECROY/inf_prod.asp

Séance du matin (9h00 – 12h00)

  • Bases de l’oscilloscope numérique moderne
  • Bases de l’échantillonnage
  • Intérêt des mémoires longues sur la qualité des mesures
  • Relation entre fenêtre d’enregistrement, vitesse d’échantillonnage et taille mémoire
  • Choisir le bon mode d’acquisition (normal, RIS, mode roll, etc.)
  • Quel déclenchement pour mon application (edge, pulse width, interval, etc.)
  • Mesures des signaux avec les curseurs et les paramètres
  • Mesures statistiques sur paramètres
  • Trouver rapidement des erreurs dans le signal acquis
  • Fonctions Math et FFT dans l’utilisation de tous les jours
  • Documentation des résultats de mesures

Pause déjeuner (repas offert par les organisateurs)

Séance de l’après-midi (13h30 – 16h30)

  • Ce qu’il faut savoir sur les sondes
  • Effet de la sonde sur le signal mesuré
  • Choix d’une sonde appropriée (passive, active, différentielle, sonde de courant, etc.)
  • Mesure, mise au point et analyse de systèmes à bus série tels que I2C, SPI, UART, LIN, etc.
  • Ce qu’il faut savoir sur les oscilloscopes à signaux mixtes (MSO)
  • Effectuer des mesures avec un oscilloscope mixte (déclenchement logique, déclenchement croisé, analyse, etc.)
  • FAQ

Qui doit participer?
Tous les électroniciens qui ont besoin d’effectuer des mesures précises et efficaces avec un oscilloscope numérique moderne.  Le contenu du séminaire n’est pas lié à un fabricant d’oscilloscope particulier.
Le niveau des informations contenues dans ce séminaire concerne des oscilloscopes numériques pouvant coûter de 2.000 € à 11.000 €.

Qui ne doit pas participer?
Ce séminaire ne s’adresse pas à des utilisateurs experts d’oscilloscopes à haute performance qui connaitraient déjà toutes les règles et astuces présentées ici.
Par LeCroy France
Ecrire un commentaire - Voir les 0 commentaires
Jeudi 21 février 2008 4 21 /02 /Fév /2008 12:09
Voici la nouvelle documentation  concernant le Test Compliance  PCI Express 2.0

Key Features
• SDA 13000 has the ability to acquire PCI Express 2.0 waveforms to be analyzed using SigTest (PCI-SIG Compliance Utility)

• SDA 13000 has has the 14 Masks, PLLs and 2 Jitter Filters specified by the PCI-SIG Gen2 specification
• SDA 13000 has the memory depth to acquire all 1 million UI in a single acquisition
• TRC output format is quickly analyzed using SigTest
• Easy-to-use user interface makes acquiring PCI Express 2.0 waveforms simple

Using the SDA 13000, PCI Express® 2.0 signals can be acquired and quickly analyzed using SigTest (PCI-SIG
Compliance Utility). The SDA 13000 has the memory depth required to acquire all required 1 Million UI in a
single acquisition. The acquired waveforms can be saved using the TRC format and can be quickly analyzed by SigTest. All of the powerful SDA tools can used to aid in the debugging of designs. LeCroy’s easy-to-use user interface makes it simple to setup the oscilloscope to properly acquire PCI Express 2.0 waveforms.

Built into the standard Serial Data Analysis tools are the 14 Masks, 3 PLLs and 2 Jitter Filetrs specified
by the PCI-SIG in the PCI Express Gen2 specifications

PCI-Ex-2.-4.JPG















tabelau-pci-express.JPG






 
Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Lundi 18 février 2008 1 18 /02 /Fév /2008 15:44
Les détournements d’oscilloscopes sont généralement réservés aux geeks nostalgiques accros aux jeux préhistoriques, mais cette version de “Scopetris” est sans doute quelque chose que les nombreux fans de Tetris apprécieront.

Le jeu utilise l’oscilloscope comme écran. L’auteur du montage a lui-même conçu le matériel qui fait fonctionner le jeu, et dessiné chacune des pièces, ce qui donne un style assez décalé à l’ensemble. Pong peut donc aller se rhabiller. Au besoin, regardez la vidéo après le saut qui devrait achever de vous convaincre:

Par LeCroy France - Publié dans : Applications
Ecrire un commentaire - Voir les 0 commentaires
Jeudi 7 février 2008 4 07 /02 /Fév /2008 14:03
Chestnut Ridge, NY, February 6, 2008 - LeCroy Corporation announces that its SDA 13000 Serial Data Analyzer has been approved by the PCI-SIG, for PCI-Express Gen 2 Add-In card testing using SigTest. The approval from the PCI-SIG, the Special Interest Group responsible for the PCI Express industry-standard I/O interconnect technology, means that designers can use the SDA 13000 for compliance testing and validation with the confidence that their new designs will be fully compatible with the PCI-Express Gen 2 standard. The SDA 13000 oscilloscope offers designers the world’s most advanced solution not only for compliance testing but, more importantly, for debugging PCI-Express Gen 2 signals and thus determining the root causes of noncompliance.

"The PCI bus is one of the most successful standards in history and is the main general-purpose bus in virtually every desktop computer throughout the world. Its flexible design has allowed it to keep pace with increases in CPU performance and data capacity. LeCroy is committed not only to having the best PCI compliance solutions but also to assisting engineers gain insight during the debugging process in order to validate performance," says Christopher Busso, LeCroy Product Marketing Manager.

An exhaustive, data cross-correlation process of LeCroy’s test methodology for add-in card testing preceded acceptance by the PCI-SIG. With more than 900 members, the PCI-SIG not only validates LeCroy’s leadingedge test solutions, it also provides the environment in which LeCroy can effectively work with developers of PCI buses and products utilizing PCI technology to validate performance and bring products to market faster and with a higher degree of confidence.

The SDA 13000 serial data analyzer is an oscilloscope specifically designed to meet the needs of the next generation serial data standards. When used with the SigTest tool for compliance testing, the SDA 13000 provides the best solution for compliance testing and debug of PCI-Express Gen 2 signals. LeCroy’s PCIExpress Gen 2 debug package works completely within the existing SDA software structure. LeCroy’s latest software release will include 14 new compliance masks, 3 PLLs and 2 Jitter Filters as defined by the PCI-SIG Gen 2 specification.

Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Mardi 29 janvier 2008 2 29 /01 /Jan /2008 10:16
 
 
Pleins feux sur:
 
 
 

Optimisez votre budget 2008

Packs oscilloscopes signaux mixtes
LeCroy propose ses oscilloscopes WaveSurfer Xs 200 MHz et 400 MHz couplés à l’option Signaux Mixtes MS-250 à partir de seulement
€ 6.992/CHF 11'496.

Pack Oscilloscope Sampling avec analyse intégrité de signal/TDR
L’oscilloscope sampling SDA100G est déja proposé en ex-démo pour un prix très compétitif, couplé à deux modules électriques ST-20 permettant la mesure TDR à partir de seulement
€ 27.900/CHF 44'220.

     
 
   
   
   
Nouveautés en oscilloscopie:  
   
   

Bulletin Oscilloscope IEEE:
Comment améliorer et qualifier l’analyse spectrale avec un oscilloscope numérique
Comment améliorer et qualifier l’analyse spectrale avec un oscilloscope numérique Cet article traite d’une procédure de mesure à partir de la FFT, ce qui a été implémenté dans un module logiciel pour des oscilloscopes large bande. Ce module logiciel peut être installé sur un oscilloscope dans le but d’améliorer ses performances en terme de résolution fréquentielle et de possibilité d’auto-configuration, permettant l’auto-estimation de l’imprécision de mesure des amplitudes et fréquences des composantes spectrales du signal.

Articles techniques:

EyeDoctor maintenant disponible sur les oscilloscopes rapides
Eye Doctor, pack logiciel pour le sondage virtuel et l’émulation d’égalisation de LeCroy, est maintenant disponible en option pour la série d’oscilloscopes SDA.

Nouvelle sacoche de transport pour les oscilloscopes WaveJet
Le faible encombrement des WaveJet facilite leur transport du labo au terrain de mesure. L’accessoire WJ-CASE fait office de sacoche de transport et de protection de face avant. Il suffit de glisser le WaveJet dans la sacoche et de rabattre le capot de face avant pour le transporter. Inutile de sortir le WaveJet de sa sacoche pour l’utiliser, retirer simplement le capot.

La société Picosecond utilise un LeCroy SDA18000 pour présenter un nouveau produit TDR
La société Picosecond sera présente à DesignCon 2008. Picosecond présentera une demonstration d'un nouveau prototype TDR couplé à notre oscilloscope temps réel SDA18000 et fera également une démonstration de la source TDR/TDT la plus rapide du monde.

Venez nous voir à RTS Embedded Systems 2008 à Paris Porte de Versailles
Venez nous voir à RTS Embedded Systems 2008 à Paris du 1 au 3 Avril 2008, Hall 8 – Stand A16, et essayez les derniers oscilloscopes et analyseurs de protocole. Cliquez ici pour recevoir votre invitation gratuite.

Nouveaux séminaires internet:

Promotions Oscilloscopes Hiver 2008
Jetez un oeil a nos dernières promotions, packs et ventes d’appareils de démo.

Nouvelles notes d’applications

Datasheets & Brochures d’oscilloscopes

 
   
   
Nouveautés analyse de protocole:  
   
   
Nouvel analyseur de protocole Summit T2-16 PCI Express

Programme d’upgrade PCI Express 2.0 Summit PETRACER I/O board

Mise à jour majeure du seul 6Gb/s SAS/SATA Host et Device Emulator de l’industrie

Lancement international de formations sur les principaux protocoles de communications

Aperçu des solutions protocole de LeCroy

Nouvelle note d’application

Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Mercredi 23 janvier 2008 3 23 /01 /Jan /2008 11:12
undefined


ORGANISATION D'UNE JOURNÉE TEST & MESURE SIMTEC
Exposition et conférences gratuites
 
à TOULOUSE
le Jeudi 7 Février 2008
 
Le 7 Février prochain, plus de 80 entreprises représentant plus de 500 marques accueilleront les Industriels de la région pour présenter leurs dernières solutions dans le domaine de l'Instrumentation de Mesure, du Test, de la Conversion d’énergie, du Contrôle et de la Régulation, des Capteurs et de la CEM.
Il s’agit d’un concept simple : Une exposition de matériel sur table, un accueil convivial et un contact direct avec les commerciaux des sociétés les plus représentatives du marché de la Mesure Électronique.
 
Cette Journée s’adresse à tous ceux qui développent, produisent ou réparent du matériel à base d’électronique :
- Aux Dirigeants qui désirent suivre les évolutions technologiques pour guider leur stratégie d’investissement
- Aux Chefs de projets, aux responsables de laboratoires et de production qui recherchent les solutions de la productivité
- Aux Ingénieurs et Techniciens qui souhaitent du matériel à la pointe de la technologie

 
Venez nous rendre visite le Jeudi 7 Février 2008 :
 
au Centre de Congrès Pierre Baudis
11 esplanade Compans Caffarelli - 31000 TOULOUSE
 
 
PROGRAMME DE LA JOURNEE :
 
>>> Exposition de 9h00 à 12h30 et de 14h00 à 16h30
 
>>> Conférences :
 A 10h30 - conférence du Comité Test SIMTEC
"Les techniques & les moyens de test :
leurs évolutions, leur efficacité, leur complémentarité"
 
A 14h00 - conférence du Comité Maintenance SIMTEC
" Maintenance & Métrologie :
critères et outils d'aide à la décision"
 
Pour plus de renseignement et inscription en ligne, le web :
http://www.fmpromotion.com


Par LeCroy France - Publié dans : Actualites
Ecrire un commentaire - Voir les 0 commentaires
Créer un blog gratuit sur over-blog.com - Contact - C.G.U. - Signaler un abus - Articles les plus commentés